Appendix e - startup data sequences, E.1 - system connected to ird data, As detailed in – KVH Industries TracVision S2 User Manual

Page 56: Appendix e, Appendix e startup data sequences, E.1 system connected to ird data

Advertising
background image

Appendix E
Startup Data Sequences

The data on the following pages presents the startup data
sequences registered by the TracVision S2. The first section shows
the sequences registered by a system that is connected to an IRD
low-speed data port. The second section shows the sequences
registered by a system that is NOT connected to an IRD low-speed
data port. Both sections show two routines. One is the standard,
full initialization routine; the second is that registered by
TracVision S2 if it is turned on and acquires the satellite via the
“Instant On” operation (described in

Section 3, “Using Your

TracVision S2”

). These sequences can be recorded using the data

port and a PC.

E.1

System Connected to IRD Data

Standard Startup Sequence

?PGM

KVH TracVision S2 Rev X - Version X.XX - Serial Number XXXXXXXX

Limit Switch Test

Limit Switch Status: PASS-----------------PASS is expected

*** Initializing IRD ***

..

IRD STATUS: PASS DSS --------------------PASS is expected with success2ul IRD identification

Saved Sat Pos: EL = 33.4

*** Averaging Background Noise ***

+POS: 45.0 26.6 735

+POS: 57.9 20.0 1004

+POS: 232.0 20.0 812

+POS: 25.6 20.0 898

Average Noise Level = 957

Noise Threshold = 1781

Saved Sat Pos: EL = 33.4

*** Entering Search Mode 1 ***

+POS: 80.9 32.1 1217

+POS: 44.6 33.4 853

Satellite Found: AZ = 327.7, EL = 33.4, RF = 2476

+POS: 306.4 33.4 1020

*** Initializing Finetune ***-------------Peaking the satellite signal

+POS: 327.7 33.4 2827

E-1

Startup Data Sequences

54-0196 Rev. A

Advertising