E.2 - system not connected to ird data, E.2 system not connected to ird data, Standard startup sequence – KVH Industries TracVision S2 User Manual

Page 58

Advertising
background image

E.2

System Not Connected to IRD Data

Standard Startup Sequence

?PGM

KVH TracVision S2 Rev X - Version X.XX - Serial Number XXXXXXXX

Limit Switch Test

Limit Switch Status: PASS-----------------PASS is expected

*** Initializing IRD ***

Send APG OSD On

Try MPG IRD Type

Send MPG OSD On

Switch Back to Echostar IRD Type

Send APG OSD On

Try MPG IRD Type

Send MPG OSD On

Switch Back to Echostar IRD Type

IRD STATUS: FAIL None -------------------FAIL is expected with no IRD data connection

Saved Sat Pos: EL = 33.5

*** Averaging Background Noise ***

+POS: 45.0 26.3 762

+POS: 62.1 20.0 1111

+POS: 223.5 20.0 1082

Average Noise Level = 985

Nor = 1826

Saved Sat Pos: EL = 33.5

*** Entering Search Mode 1 ***

+POS: 193.4 30.1 1098

+POS: 205.8 33.5 878

Satellite Found: AZ = 330.0, EL = 33.5, RF = 2150

+POS: 0.9 33.5 586

+POS: 331.2 33.5 2173

*** Initializing Finetune ***-------------Peaking the satellite signal

+POS: 331.2 33.5 2197

+POS: 331.8 34.1 2177

Signal Peaked: AZ = 331.79, EL = 33.50, RF = 2226

*** Tracking Satellite ***

+POS: 331.7 33.4 2154

+POS: 331.7 33.4 2148

+POS: 331.7 33.4 2167

Saved Sat Pos: AZ = 331.75, EL = 33.43

+POS: 331.7 33.4 2155

+POS: 331.7 33.4 2132

+POS: 331.7 33.4 2153

Switch held: wrong satellite--------------SAT SELECT switch pressed

Exclude: No longer search AZ = 331.7, EL = 33.4

E-3

Startup Data Sequences

54-0196 Rev. A

Advertising