5.6

Replacing the Antenna Gyro
Assembly

1. Remove the main PCB cover, as described in

“Removing the Main PCB Cover” on page 106.

2. Using a

3

8

" nut driver/socket, remove the four nuts

and washers securing the antenna gyro to the
reflector bracket (see Figure 5-8). The nut on the
bottom right also secures a cable clamp. Set the
nuts, washers, and cable clamp aside.

3. Disconnect the antenna gyro Molex connector

from the main PCB (see Figure 5-3 on page 107).
Remove the old antenna gyro assembly.

4. Connect the new antenna gyro’s Molex connector

to the main PCB.

5. Replace the antenna gyro gasket (see Figure 5-8).

Maintenance

54-0147

111

Make sure the cable passes
through the PCB access slot to
protect the wires from the edge of
the PCB frame.

Gyro

Gasket

Bracket

Figure 5-8
Replacing the Antenna Gyro
Assembly