KVH Industries TracVision G4 User Manual

Page 138

Advertising
background image

GyroTrac Data Outputs

54-0147

147

NMEA2 Magnetic Heading (HDG)

Communication:

4800 baud, 1 start bit, 8 data bits, 1 stop bit,
no parity

Update rate:

Selectable at 1 to 20 Hz (10 Hz default)

Sentence type:

$HCHDG,XXX.X, *hh <cr> <lf>

Sentence breakdown:

HCHDG

NMEA talker and sentence ID

XXX.X

Stabilized magnetic heading in
degrees and tenths

*

ASCII hex 0x2A

hh

Checksum

cr

Carriage return, ASCII hex 0x0D

lf

Line feed, ASCII hex 0x0A

NMEA3 True Heading (HDT)

Communication:

4800 baud, 1 start bit, 8 data bits, 1 stop bit,
no parity

Update rate:

Selectable at 1 to 20 Hz (10 Hz default)

Sentence type:

$HCHDT,XXX.X,T *hh <cr> <lf>

Sentence breakdown:

HCHDT

NMEA talker and sentence ID

XXX.X

Stabilized true heading in
degrees and tenths

T

True heading, ASCII hex 0x54

*

ASCII hex 0x2A

hh

Checksum

cr

Carriage return, ASCII hex 0x0D

lf

Line feed, ASCII hex 0x0A

Table G-2
NMEA2 Magnetic
Heading Output

Table G-3
NMEA3 True
Heading Output

True Heading is only available
when GPS data input is received by
the ADCU. Refer to “Connecting
GPS for True North Capability” on
page 36

for complete details.