Typical installation, Get to know your water heater - gas models – Kenmore THE ECONOMIZER 153.33206 User Manual

Page 8

Advertising
background image

8

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A

Vent

Pipe–Exhaust

B

Vent

Terminal

C

Vent

Adapter-Rubber

Boot

D

Blower

Assembly

E Cold Water Inlet

F Inlet Water Shut-off Valve

G

Union

H Inlet Dip Tube

J

Anode**

FIGURE 1.

K Hot Water Outlet

L Outlet Receptacle (115 VAC)

M Temperature-Pressure Relief Valve

N

Flue

O

Flue

Baffl e Assembly**

P

Insulation

Q

Control

Harness

R Rating Plate

S Gas

Supply

T Manual Gas Shut-off Valve

U Ground Joint Union

V Drip Leg (Sediment Trap)

W Drain Valve

X Gas Valve-Thermostat

Y Drain

Pan

Z Air Intake Screen - Base Pan

A A Inner Door
B B Outer Door
C C HSI Burner Assembly
D D Air Intake Screen -

Blower

Assembly

E E FV Sensor Assembly

NATURAL HOT SURFACE IGNITER & MAIN BURNER

HOT

SURFACE

IGNITOR

SENSOR

PROPANE HOT SURFACE IGNITER & MAIN BURNER

TEMPERATURE INDICATORS

TEMPERATURE ADJUSTMENT BUTTONS

HOT

SURFACE

IGNITOR

SENSOR

*CAUTION: 115 VAC IN CONTROL HARNESS
AND INSIDE OUTER DOOR

* ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS.

** LOCATED UNDER THE BLOWER ASSEMBLY.

GAS MODELS
WITH HOT SURFACE IGNITION
& 2”, 3” OR 4” PVC VENT CAPABILITY

Advertising