Installation specification – Kohler 8030A User Manual

Page 3

Advertising
background image

3

1071288-AN2-F 09/03/12

INSTALLATION

SPECIFICATION

Before you Begin
1. Turn off the water supply.

2. Make sure that the Watertile Rainshower is installed by a competent installer.

3. Before installation carefully inspect the new fixture for any signs of damage.

4. Kohler Co. reserves the right to make revisions in the design of products without

notice.

Pressures
The minimum recommended operating pressure is 1.5 bar.

For multiple outlets an operating pressure of 3.0 bar or greater is recommended to

ensure optimum performance.

Plumbing Connections
Mixed water from a valve must be connected to the inlet of a pressure balance

loop.
Building in Depth
Note!
Minimum building in depth is 79 mm. It is recommended that a minimum stud

wall cavity of 100 mm is provided to ease installation.