A-8

INSTALLATION

COMMANDER 300

A-8

CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS

ELECTRIC SHOCK can kill.

Shut off welder before making any
electrical connections.

------------------------------------------------------------------------

CONNECTION OF THE LN-25 TO THE
COMMANDER 300

The LN-25 with or without an external contactor may
be used with the Commander 300. See the appropriate
connection diagram in the DIAGRAMS section.

NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the Commander 300.

Shut the welder off.

For electrode Positive, connect the electrode cable

from the LN-25 to the

+

terminal of the welder and

work cable to the

-

terminal of the welder. For elec-

trode Negative, connect the electrode cable from the
LN-25 to the

-

terminal of the welder and work

cable to the

+

terminal of the welder.

Attach the single lead from the front of the LN-25 to

work using the spring clip at the end of the lead. This
is a sense lead to supply current to the wire feeder
motor; it does not carry welding current.

Set the SELECTOR switch to the

CV-WIRE

posi-

tion.

Set the

WELDING TERMINALS

switch to

WELD

TERMINALS ON

Adjust the

ARC CONTROL

knob to desired crisp-

ness. Generally, welding is best if the

ARC CON-

TROL

is set to SOFT for MIG and CRISP for

Innershield. You may however, want to start in the
middle and adjust (as needed) from there.

Set the

IDLE

switch to the

AUTO

position. When

not welding, the Commander 300 engine will be at
the low idle speed. If you are using an LN-25 with an
internal contactor, the electrode is not energized until
the gun trigger is closed.

ELECTRIC SHOCK can kill.

If you are using an LN-25 without an
internal contactor, the electrode will be

energized when the Commander 300 is started.

------------------------------------------------------------------------

h. When the gun trigger is closed, the current sensing

circuit will cause the Commander 300 engine to go
to the high idle speed, the wire will begin to feed
and the welding process started. When welding is
stopped, the engine will revert to low idle speed
after approximately 12 seconds unless welding is
resumed.

CONNECTION OF LN-7 OR LN-8 TO THE
COMMANDER 300

Shut the welder off.

Connect the LN-7 or LN-8 per instructions on the

appropriate connection diagram in the DIAGRAMS
section.

Set the

WIRE FEEDER VOLTMETER

switch to

either

+

or

-

as required by the electrode being

used.

Set the

SELECTOR

switch to the

CV-WIRE

posi-

tion.

Adjust the

ARC CONTROL

knob to desired

Crispness. SOFT for MIG and CRISP for Innershield.

Set the

WELDING TERMINALS

switch to the

REMOTELY CONTROLLED

position.

Set the

IDLE

switch to the

HIGH

position. When

not welding, the Commander 300 engine will be at
the low idle speed.

WARNING

CAUTION