Troubleshooting, Caution – Lincoln Electric COMMANDER 300 IM700-D User Manual

Page 38

Advertising
background image

E-4

TROUBLESHOOTING

E-4

COMMANDER 300

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

No welding power output.

Welder has output and no control.

No auxiliary power.

1. Welding terminals switch in wrong

position. Place switch in

WELD

TERMINALS

position when weld-

ing without welding terminal con-
trol cable. Refer to Operation
chapter for proper switch function.

1. Poor remote kit connection.

Check connections.

2. Faulty remote kit. Replace if nec-

essary.

1. Open circuit breakers. Reset

breakers. If breakers keep trip-
ping check connections to auxil-
iary receptacles. Also make sure
load does not exceed receptacles
current rating. Refer to Auxiliary
Connections in the Installation
and Operation chapters.

2. Faulty connections to auxiliary

receptacles. Check connections.

3. Faulty auxiliary circuit wiring.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.