Operation, Controls and settings, B-3 engine controls (items 1 through 8) – Lincoln Electric COMMANDER 300 IM700-D User Manual

Page 20

Advertising
background image

B-3

OPERATION

B-3

ENGINE CONTROLS (Items 1 through 8)

1. RUN- STOP SWITCH
When placed in the

RUN

position, this switch ener-

gizes the fuel solenoid and other electric accessories.
When placed in the

STOP

position, the flow of fuel to

the injection pump is stopped to shut down the engine.
(Note: If the switch is left in the "RUN" position and the
engine is not running, the fuel solenoid will be engaged
for 15 seconds and then shut down. This is to protect
the battery from discharge. After 15 seconds, the Run
/ Stop switch must be toggled off then on before start-
ing.)

2. START PUSH BUTTON
Energizes the starter motor to crank the engine. With
the engine "Run / Stop" switch in the "Run" position,
push and hold the Start button to crank the engine;
release as the engine starts. Start button must be
depressed for a minimum of two seconds. Do not press
while engine is running since this can cause damage to
the ring gear and/or starter motor.

3. FUEL LEVEL GAUGE AND LIGHT
(K1585-2 only on codes 10871 and below) -
Displays the level of diesel fuel in the 25-gal-
lon(94.6 liters) fuel tank. The yellow light turns on when
the fuel gage reaches the reserve level. For Codes
10950 and 10951 yellow light is not required. Once the
reserve level is reached, the engine protection system
will shut down the engine after 30 minutes of operation.
The machine can be restarted and operated for an
additional 30 minutes before the protection system will
shut down the engine. This ability to override the
engine protection is to allow the operator to

finish up

if necessary. The operator must watch the fuel level
closely to prevent running out of fuel and having to
bleed the system.

COMMANDER 300

CONTROLS AND SETTINGS

All welder and engine controls are located on the case front panel. Refer to Figure B.1 and the explanations that
follow.

Figure B.1 Case Front Panel Controls

1

2

3

4

5

6

7

8

9

19

12

17

18

14

16

20

9

FUEL

TEMP

WATER

PRESS

OIL

AMPS

10

11

15

13

Advertising