Warning, Wiring diagram - 120 volt, Wiring - 120 volt – Lucent Technologies MPE-33R User Manual

Page 10: Nl1 ground, Ground g

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

10

10

WIRINg DIAgRAM - 120 VOLT

Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance

on the left side.
CAUTION: LAbEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICINg CONTROLS. WIRINg ERRORS CAN CAUSE IMPROPER AND DAN-

gEROUS APPLIANCE OPERATION.

WIRINg - 120 VOLT

Figure 19

L1 = BLACK (POWER)

L2 = ORANGE (POWER)

G = GREEN (GROUND)

N = WHITE (COMMON)

N1 = BLUE (COMMON)

N2 = BLUE (COMMON)

HOME POWER

SUPPLy

120 VAC

Control Panel

Flame / Ember

On/Off Switch

Temperature Sensor

Control Panel

(power on/off)

Control Panel

Heater On/Off

Switch

Wall Thermostat

Wall Switch

(power on/off)

Outside Switches

Outer Wall

Heater 1 (L)

Heater 2 (L)

Fan Motor (L)

Flame Motor (L)

Light (L)

L-R1

L-R2

L-FAN

L-M

P-L

L-LIGHT

SIP3

SIP4

TEM
.

SIP6

K-H

K-P

N-FLAM

E

L-FLAM

E

N-LIGH

T

POWER-N

N-F
AN

N-M

P-TRA.

SIP11

SIP7

T-P

SIP13

LIGHT

Transformer

Circuit

Board

SIP2

REMOTE

MAIN POWER

L1

L1

L2

N1

N2

N

N

PTC

T105° C

Remote Sensor

GROUND

WARNINg

Do not install or operate this fireplace through a switch wired in the 120 VAC or 240 VAC circuits. The only approved

wiring for a switch is through the low voltage circuit (24 VAC) as shown on Page 14.

HOME POWER -

SUPPLy 120 VAC

FIREPLACE WIRE

HARNESS

See Power Supply Specifications on Page 3.

N

L1

gROUND

yELLOW AND gREEN

ORANgE

bLACK

bLUE

bLUE

WHITE

N

L1

N1

N2

L2

120 V 1600 W

120 V AC

gROUND

g

IF THE APPLIANCE IS TO bE HARD WIRED

IN, THE POWER CORD MUST bE REMOVED

(SEE INSTRUCTION #2 ON PAgE 5).

Figure 20

Advertising