MINIMUM CLEARANCES TO COMbUS-

TIbLES

Mantel Clearance: Combustible and Non-com-

bustible mantels may be installed at any height

above the top of the face of fireplace.

Cat. No. H3427
Model: MPE-33R
Description: Merit Plus Electric Fireplace,

33” Radiant

Shipping Weight: 81 lb.'s (36.75 KG)
Packaging:

41” x 17 3/4” x 33 1/2”
(1040 mm x 451 mm x 850 mm)
14.1 cu. ft.
Power Requirements:
(120 Volt, 60 Hz.)

Rated Wattage - 1600 Watts

Amperage - 13.33 Amps

(240 Volt, 60 Hz.)

Rated Wattage - 3000 Watts

Amperage - 12.5 Amps

Blower CFM: 83 CFM
(120 V): 5,461 BTU/HR
(240 V): 10,239 BTU/HR

FIREPLACE SPECIFICATIONS

This appliance is an electric fireplace designed

to be framed in with combustible materials (up

to the edge of the appliance). A drywall lip at

the top of the fireplace and 4 nailing flanges

on the sides of the appliance is provided to

facilitate installation.

Hearth Protection: A hearth is not mandatory,

but it is recommended for aesthetic purposes.

Secure the hearth extension to the floor to

prevent possible shifting. Do no block the air-

flow beneath the appliance (read the following

WARNING).

Clearances

Sides

0 inches - 0 mm

Floor

0 inches - 0 mm

Top

0 inches - 0 mm

Table 2

WARNINg

Electrical wiring must comply

with local building codes and

other applicable regulations to

reduce the risk of fire, electrical

shock and injury to individuals.

IMPORTANT

Any electrical re-wiring of this

appliance must be done by a

qualified electrician.

WARNINg

Do not use this fireplace if any

part of it has been underwater.

Immediately call a qualified

service technician to inspect the

fireplace and replace any part of

the electrical system which has

been under water.

3. Wire a dedicated, properly fused circuit with

an Amp rating for the appropriate voltage

(120 V - 15 Amps or 240 V - 20 Amps).

A dedicated circuit is required to prevent

overloading a house circuit in cases of having

multiple appliances on the same circuit.

Use an outlet that is protected by a ground

fault circuit interrupter where required by

electrical code.

4. (If applicable) Make wall mount wall switch

or wall thermostat connections as outlined

on Pages 11 & 12.

5. Perform a function test. See Manual Control

Panel Operation on Page 6 and Remote

Control Operation on Page 7.

ELECTRICAL CONNECTIONS

Refer to the electrical diagrams on Pages 10

to 14.

PRE-INSTALLATION

before you Start

Check appliance for any concealed damage.

DETAILED INSTALLATION STEPS

1. Complete the framing opening to the dimen-

sions specified in Figure 2.

2. Prepare the connections to power source:

120 Volt Connections - Locate the power

cord on the left side of the unit and connect

it to the outlet installed during the framing

(see Figure 2). Verify that the power to the

receptacle is off.

Hard wired installation:

Ensure that there is a minimum of 8" of the

service cable for connection to the junction

box on the fireplace.

- Loosen four screws to remove the junction

box cover plate.

- Disconnect and remove the 120 Volt power

cord from the fireplace wires.

- Position the fireplace into the framed-in

opening. Attach fireplace to frame using

nailing flanges provided.

- Complete the wiring to the fireplace as

shown on Page 10.

- Place all wire connectors inside the junction

box.

- Attach junction box cover plate with four

screws.

240 Volt Connections - Ensure that there

is a minimum of 8" of the service cable

for connection to the junction box on the

fireplace.

- Loosen four screws to remove the junction

box cover plate.

- Disconnect and remove the 120 Volt power

cord from the fireplace wires.

- Position the fireplace into the framed-in

opening. Attach fireplace to frame using

nailing flanges provided.

- Complete the wiring to the fireplace as

shown on Page 11.

- Place all wire connectors inside the junction

box.

- Attach junction box cover plate with four

screws.

The fireplace wires L1, L2, N, N1, N2 and

G are attached to the rear of the junction

box cable clamp for easy access.