Warning, Wiring diagram - 240 volt, Wiring - 240 volt – Lucent Technologies MPE-33R User Manual

Page 11

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

11

WIRINg DIAgRAM - 240 VOLT

Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance

on the left side.
CAUTION: LAbEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICINg CONTROLS. WIRINg ERRORS CAN CAUSE IMPROPER AND DAN-

gEROUS APPLIANCE OPERATION.

WIRINg - 240 VOLT

Figure 21

Figure 22

HOME POWER SUPPLy

240 VAC

120 V (L1) + 120 V (L2) = 240 V

FIREPLACE WIRE

HARNESS

Control Panel

Flame / Ember

On/Off Switch

Control Panel

Heater On/Off

Switch

.

Wall Thermostat

Wall Switch

(power on/off)

Outside Switches

Control Panel

(power on/off)

Transformer

Temperature Sensor

Remote Sensor

PTC

Heater 1 (L)

Heater 2 (L)

Fan Motor (L)

Flame Motor (L)

Light (L)

L-R1

L-R2

L-FAN

L-M

P-L

L-LIGHT

L1

L2

N1

N2

N

MAIN POWER

L1

L2

N

N-FLAM

E

L-FLAM

E

SIP4

K-P

SIP2

REMOTE

SIP3

K-H

TEM
.

SIP6

N-LIGH

T

POWER-N

N-F
AN

N-M

P-TRA.

SIP11

SIP7

T-P

LIGHT

SIP13

Circuit

Board

GROUND

T105° C

HOME POWER

SUPPLy

240 VAC

120 VAC

120 VAC

WHITE

bLACK

ORANgE

bLUE

bLUE

yELLOW AND gREEN

gROUND

N

L1

L2

240 V 3000 W

gROUND

N

L1

L2

N1

N2

See Power Supply Specifications on Page 3.

WARNINg

Do not install or operate this fireplace through a switch wired in the 120 VAC or 240 VAC circuits. The only approved

wiring for a switch is through the low voltage circuit (24 VAC) as shown on Page 14.

L1 = BLACK (POWER)

L2 = ORANGE (POWER)

G = GREEN (GROUND)

N = WHITE (COMMON)

N1 = BLUE (COMMON)

N2 = BLUE (COMMON)

THE 120 VOLT POWER CORD INSTALLED ON

THIS APPLIANCE MUST bE REMOVED (SEE

INSTRUCTION #2 ON PAgE 5).

g