Interface 0, alternate setting 1 (i0:a1), Table 8 . interface descriptor, i0:a1, Table 9 . bulk out endpoint descriptor, i0:a1:e1 – Lucent Technologies USS-720 User Manual

Page 35: Table 10 . bulk in endpoint descriptor, i0:a1:e2, Usb port, Instant usb, Ieee

Advertising
background image

Preliminary Data Sheet, Rev. 5

USS-720

Instant USB

September 1999

USB-to-

IEEE

1284 Bridge

Lucent Technologies Inc.

5-9

13

USB Port

(continued)

Interface 0, Alternate Setting 1 (I0:A1)

Table 8. Interface Descriptor, I0:A1

Offset

Field

Size

Value

Description

0

bLength

Byte

0x09

Size of this descriptor in bytes.

1

bDescriptorType

Byte

0x04

Interface descriptor type.

2

bInterfaceNumber

Byte

0x00

Zero-based value identifying the number of this interface.

3

bAlternateSetting

Byte

0x01

Value used to select this alternate interface.

4

bNumEndpoints

Byte

0x02

Number of endpoints used by this descriptor.

5

bInterfaceClass

Byte

0x07

Printer class.

6

iInterfaceSubClass

Byte

0x01

Printer subclass.

7

bInterfaceProtocol

Byte

0x02

Bidirectional interface.

8

iInterface

Byte

0x00

Index to string describing this interface.

Table 9. Bulk Out Endpoint Descriptor, I0:A1:E1

Offset

Field

Size

Value

Description

0

bLength

Byte

0x07

Size of this descriptor in bytes.

1

bDescriptorType

Byte

0x05

Endpoint descriptor type.

2

bEndpointAddress

Byte

0x01

This is an Out endpoint, endpoint number 1.

3

bmAttributes

Byte

0x02

This is a Bulk endpoint.

4

wMaxPacketSize

Word 0x0040 Maximum data transfer size.

6

bInterval

Byte

0x00

Does not apply to Bulk endpoints.

Table 10. Bulk In Endpoint Descriptor, I0:A1:E2

Offset

Field

Size

Value

Description

0

bLength

Byte

0x07

Size of this descriptor in bytes.

1

bDescriptorType

Byte

0x05

Endpoint descriptor type.

2

bEndpointAddress

Byte

0x82

This is an In endpoint, endpoint number 2.

3

bmAttributes

Byte

0x02

This is a Bulk endpoint.

4

wMaxPacketSize

Word 0x0040 Maximum data transfer size.

6

bInterval

Byte

0x00

Does not apply to Bulk endpoints.

Advertising