Epp address register, Epp data register, Table 24 . epp address register – Lucent Technologies USS-720 User Manual

Page 44: Table 25 . epp data register, Ieee 1284 port, Instant usb, Ieee

Advertising
background image

5-18

Lucent Technologies Inc.

USS-720

Instant USB

Preliminary Data Sheet, Rev. 5

USB-to-

IEEE

1284 Bridge

September 1999

13

IEEE 1284 Port

(continued)

EPP Address Register

EPP Data Register

Table 24. EPP Address Register

EPP Address Register

Address: 3

Bit

7

6

5

4

3

2

1

0

Symbol

A7

A6

A5

A4

A3

A2

A1

A0

Access

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Default

X

X

X

X

X

X

X

X

Bit

Symbol

Bit Description

7—0

A7—A0

EPP Address. This register is equivalent to and operates in the same manner as the
EPP Address Register in a standard host-side parallel port controller chip. The
register is writable when Auto Mode is 0 and the Mode field in the Extended Control
Register is set to 100. A write to this register initiates an EPP address write transfer
on the parallel port. The register is always readable. When the Mode is set to 100, a
read access will initiate an EPP address read transfer on the parallel port, and the
value returned will be the address value read from the peripheral. Reads when not in
Mode 100 will return whatever value has been previously latched, but will not have
any effect on the parallel port.

Table 25. EPP Data Register

EPP Data Register

Address: 4

Bit

7

6

5

4

3

2

1

0

Symbol

D7

D6

D5

D4

D3

D2

D1

D0

Access

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Default

X

X

X

X

X

X

X

X

Bit

Symbol

Bit Description

7—0

D7—D0

EPP Data. This register is equivalent to and operates in the same manner as the EPP
Data Register in a standard host-side parallel port controller chip. The register is writ-
able when Auto Mode is 0 and the Mode field in the Extended Control Register is set
to 100. A write to this register initiates an EPP data write transfer on the parallel port.
The register is always readable. When the Mode is set to 100, a read access will
initiate an EPP data read transfer on the parallel port, and the value returned will be
the data value read from the peripheral. Reads, when not in Mode 100, will return
whatever value has been previously latched, but will not have any effect on the
parallel port.