Installation, Technical specifications – Lincoln Electric INVERTEC V450-PRO User Manual

Page 10

Advertising
background image

INVERTEC V450-PRO (CE)

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS -

INVERTEC V450-PRO (CE)

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS

380-415V

50/60HZ.

INPUT

VOLTAGE /

FREQUENCY

380-415

50/60 Hz

HEIGHT

26.10 in

663 mm

WIDTH

19.86 in

505 mm

DEPTH

32.88 in

835 mm

WEIGHT

278 lbs.

126 kg.

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

63 AMP

TYPE 75°C

GROUND WIRE IN

CONDUIT AWG

(MM

2

) SIZES

10 (6)

TYPE 75°C

COPPER WIRE IN

CONDUIT AWG

(MM

2

) SIZES

8 (10)

PULSE

VOLTAGE

RANGE

5 - 55 VDC

AUXILIARY

POWER

220 VAC AT

5 AMPS

24VAC

42VAC at

10 AMPS

PULSE AND

BACKGROUND

TIME RANGE

100 MICRO SEC. -

3.3 SEC.

PULSE

FREQUENCY

0.15 - 1000 Hz

INPUT

CURRENT

I

1

max

48

INPUT

CURRENT

I

1

eff

37

OUTPUT

CONDITIONS

400A@36V 100%

500A@40V 60%

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-40°C to +40°C

MIG/MAG

FCAW

SMAW

GTAW

Pulse

50-500 Average Amps
40-500 Average Amps
55-500 Average Amps

5-500 Average Amps

5-750 Peak Amps

30-76

76
76

18-76

76

OPEN CIRCUIT VOLTAGE PROCESS CURRENT RANGE (DC) CURRENT

Advertising