Troubleshooting, Caution – Lincoln Electric INVERTEC V450-PRO User Manual

Page 33

Advertising
background image

E-4

TROUBLESHOOTING

E-4

INVERTEC V450-PRO (CE)

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Thermal symbol is lit

Wire feeder won

t work. Apparently

no power to wire feeder

1. Check for proper fan operation.

2. Check for material blocking intake

or exhaust louvers.

3. Blow air in the rear louvers to

clear dirt from the fan.

1. Check circuit breakers by the wire

feeder receptacles on the lower
front panel. Reset

2. Check the control cable between

the power source and the wire
feeder for continuity.

1.If all recommended possible areas

of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.

Advertising