Types of Remote WELD TERMINAL Control
•
The Invertec V450-PRO (CE) Weld Terminals can
be controlled from each of the MS-style connectors.
The circuit has a nominal OCV of 15VDC and
requires a dry contact closure (less than 100 ohms)
to activate the output of the Invertec V450-PRO
(CE).
•
14-Pin MS-style connector, the Weld Terminals are
controlled from pin C (lead 2) and pin D (lead 4). Pin
C is positive.
•
6-Pin MS-style connector, the Weld Terminals are
controlled from pin D (lead 2) and pin E (lead 4). In
the 6-pin MS-style connector pin D is positive.
LIMITATIONS
•
The V450-PRO (CE) is not recommended for
processes other than those listed.
•
The V450-PRO (CE) can only be used with the rec-
ommended equipment and options.
RECOMMENDED PROCESSES
Properly equipped, the Invertec V450-PRO (CE)
supports GMAW-P, FCAW, SMAW, GTAW and
CAC-A processes for a variety of materials, includ-
ing mild steel, stainless steel, cored wires, and alu-
minum.