OPERATION

B-2

PIPELINER 200D

Cranking System

A 12V electric starter is standard.

Air Cleaner

Heavy duty two-stage dry type

Exhaust

A muffler and stainless steel exhaust outlet pipe are
standard.

Engine Hour Meter

A meter to record the hours of operation.

ENGINE OPERATION

Operate the welder with the doors closed. Leaving
the doors open changes the designed air flow and can
cause overheating.

STARTING THE PIPELINER 200D PERKINS
104.22 DIESEL ENGINE

1. Turn the

IDLER

switch to

HIGH

.

2. Turn the

IGNITION

switch to

ON

.

3. Press the Glow Plug button for 20 to 30 seconds.

(maximum 60 seconds).

4. Press the Start button. When the engine starts run-

ning, release both buttons. If the engine fails to start
in 20 seconds, wait 30 seconds and repeat the
above procedure.

5. Observe the oil pressure. If no pressure shows

within 30 seconds, stop the engine and consult the
engine operating manual. To stop the engine, turn
the

IGNITION

switch to

OFF

.

6. If the engine protection warning light comes on dur-

ing cranking or after start up, the

IGNITION

switch

must be turned

OFF

to reset the engine protection

system.

7. Allow the engine to run at high idle speed for sever-

al minutes to warm the engine. Stop the engine and
recheck the oil level after allowing sufficient time for
the oil drain into the pan. If the level is down, fill it to
the full mark again. The engine controls were prop-
erly set at the factory and should require no adjust-
ing when received.

COLD WEATHER STARTING

With a fully charged battery and a proper weight oil,
the engine should start satisfactorily even down to
about -15

°

F -(26

°

C). If the engine must be frequently

started at or below -15

°

F -(26

°

C), it may be desirable

to install cold-starting aides.

Note

: Extreme cold weather starting may require

longer glow plug operation

Under NO conditions should ether or other start-
ing fluids be used!

------------------------------------------------------------------------

STOPPING the ENGINE

1. Turn the

IGNITION

switch to

OFF

At the end of each day

s welding, check the crankcase

oil level, drain accumulated dirt and water from the
sediment bowl under the fuel tank and refill the fuel
tank to minimize moisture condensation in the tank.
Also, running out of fuel tends to draw dirt into the fuel
system.

When hauling the welder between job sites, close the
fuel feed valve beneath the fuel tank.

If the fuel supply is cut off or runs out while the fuel
pump is operating, air may be entrapped in the fuel
distribution system. If this happens, bleeding of the
fuel system may be necessary. Use qualified person-
nel to do this per the instructions in the MAINTE-
NANCE section of this manual.

WARNING

PIPELINER 200D WITH PERKINS 104.22
DIESEL ENGINE

TYPICAL FUEL CONSUMPTION DATA

Low idle (1400 RPM )

.33gal/hr (1.25ltrs/hr )

No Load
High idle ( 1800 Rpm )

.39gal/hr (1.48ltrs/hr )

No load
200 Amps @ 28 Volts

.67gal/hr (2.54ltrs/hr )

200 Amps @ 40 Volts

.75gal/hr (2.84ltrs/hr )

Auxiliary Power
15 Amps @ 120 Volts

.50gal/hr (1.89ltrs/hr)