Operation, Caution – Lincoln Electric PIPELINER IM769 User Manual

Page 15

Advertising
background image

B-4

OPERATION

B-4

PIPELINER 200D

When a forceful

digging

arc is required, usually for

vertical and overhead welding, use a higher

Current

Range Selector

setting and lower open circuit volt-

age. For example: to obtain 175 amps and a forceful
arc, set the

Current Range Selector

to the 240-160

position and the

Fine Current Adjustment

setting to

get 175 amps.

DO NOT attempt to set the “Current Range Selector”
between the five points designated on the nameplate.

------------------------------------------------------------------------

These switches have a spring loaded cam which
almost eliminates the possibility of setting this switch
between the designated points.

IDLER OPERATION

Start the engine with the

Idler

switch in the

High

position. Allow it to run at high idle speed for several
minutes to warm the engine. See Specifications for
operating speeds.

The idler is controlled by the

Idler

toggle switch on

the welder control panel. The switch has two posi-
tions as follows:

1.

In the

High

position, the idler solenoid acti-

vates, and the engine goes to high idle speed. The
speed is controlled by the governor.

2.

In the

Auto

/ position, the idler oper-

ates as follows:

When welding or drawing power for lights or tools
(approximately 100-150 watts minimum) from the
receptacle, the idler solenoid activates and the engine
operates at high idle speed.

When welding ceases or the power load is turned off,
a preset time delay of about 15 seconds starts. This
time delay cannot be adjusted.

If the welding or power load is not re-started before
the end of the time delay, the idler solenoid deacti-
vates and reduces the engine to low idle speed.

AUXILIARY POWER

1.80 kW of 120V DC auxiliary power at 35% duty
cycle maximum is available at the receptacle located
on the control panel.

CAUTION

Advertising