Electronic idler troubleshooting guide, Troubleshooting, Caution – Lincoln Electric PIPELINER IM769 User Manual

Page 26

Advertising
background image

E-7

TROUBLESHOOTING

E-7

PIPELINER 200D

ELECTRONIC IDLER TROUBLESHOOTING GUIDE

With Idler Control Switch in the AUTO Position,

Engine Will Not Pick Up Speed When:

The Auxiliary Power Load is Turned ON

Power Load Too Small

Try Load Above 150 Watts

Engine Does Not Pick Up Speed

Engine Picks Up Speed

1. Check Idler Circuit

Wiring and Repair as
Required.

2. Replace Current Sensor.

Engine Does Not Pick Up

Speed

1. Check Continuity of Idler

Solenoid Coil (8.5-9.0
ohms) and Replace as
Required.

2. Check for Jamming of

the Idler Solenoid
Mechanism.

3. Check Idler Circuit

Wiring and Repair as
Required.

4. Replace Idler P.C.

Board.

Current sensor may be

defective and not closed.

To Check:

Short the Lead from

current sensor to P.C. Board to the

Welder Frame.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

The Arc is Struck

N0TE:

If the engine will not idle up or down under both
weld and auxiliary load, check idler circuit wiring.
The direction of leads entering the current sensor
may be incorrect.