INSTALLATION

MAGNUM COOLER 10-I & 20-I

A-8

WATER COOLED EQUIPMENT INSTALLATION

NOTE: Magnum Coolers operate at 45 psi (3.0 bar)
(310 kPa) of pressure for Cooler 10-I and 60 psi (4.0
bar) (414 kPa) of pressure for Cooler 20-I. When used
in the demand system, the pressure in the supply
hose to the water solenoid or valve can surge to 20
psi (1.4 bar) (138 kPa) above holding pressure just
before shutdown. The holding pressure will be 60-65
psi (4.0-4.4 bar) (414-448 kPa). When using the
Magnum Cooler with other water cooled TIG, MIG and
plasma systems, consult the manufacturer’s instruc-
tion manual.

FIGURE 4

Water Cooled TIG Torch Connection

REGULATOR

FLOWMETER

GAS*

ARGON GAS

CYLINDER

COOLANT

OUT

COOLANT

IN

COOLANT*

GAS

COOLANT*

COOLANT

GAS

IN

IN

OUT OUT

COOLANT

GAS

TO WORK

POWER / COOLANT

POWER CABLE ADAPTER*

TIG TORCH

*INCLUDED IN

KP504 HOOK-UP KIT