TROUBLESHOOTING

E-4

MAGNUM COOLER 10-I & 20-I

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Pump operates, but fan does not.

Cooler trips outlet circuit breaker.

a. Internal AC circuit open.

b. Fan blade contacting heat

exchanger.

c. Fan motor failure

a. Circuit overloaded.
b. Cooler electrical component

failure.

a. Secure AC connectors on rec-

tifier bridge.

b. If fan blades are plastic,

replace. Reset fan clearance
and secure fan to motor shaft.

c. Replace fan motor with Fan

Motor and Mount Assembly.

a. Check outlet circuit breaker.
b. Replace suppressor assembly

and rectifier bridge inside of
Cooler.