Installation, A-11, Figure 8 – Lincoln Electric MAGNUM IM438-B User Manual

Page 18

Advertising
background image

A-11

INSTALLATION

MAGNUM COOLER 10-I & 20-I

A-11

K529-10 POWER INPUT CABLE WITH WATER AND
GAS LINES

The K529 power input cable connects from the front of
a Lincoln power source to the back of LN-7 and LN-7
GMA wire feeders equipped with a water solenoid
control. K529-10 is 10 ft. (3.0m) long and includes two
water hoses and a gas line. The lengths of the two
water hoses and gas line are designed for proper con-
nection to a Magnum Cooler and a gas cylinder locat-
ed on the back of a Lincoln K874, K840-1*, K841-1* or
K842-1* double cylinder undercarriage. The water
connections are 5/8-18 left hand thread while the gas
connection is 5/8-18 right hand thread. Reference
Figure 8 when using the K529 power input cable.

* Not available at time of printing.

Figure 8

K529-10 POWER INPUT CABLE CONNECTION

SHIELDING

GAS

COOLANT

OUT

WITHOUT

SOLENOID CONNECTIONS

COOLANT

COOLANT

GUN CABLE

IN
OUT

K529-XX

COOLANT

COOLANT

ELECTRODE CABLE

TO WORK

CONTROL CABLE

COOLANT

IN

NOTE:

BLUE HOSE

RED HOSE

=

COOLANT

OUT

COOLANT

IN

=

Advertising