3. Reconfigure as for a new device.

Problem No. 6

Printing by FTP, I receive an error message:
Invalid print queue
Print queue not ready

Solution No. 6

• Check that the printer is ready
• Check that Logical printer(s) are defined on the LevelOne

Printer Server. With FTP, you can print ONLY to a logical
printer.

• Reset the LevelOne Printer Server

Problem No. 7

I can’t print using LPD.

Solution No. 7

Try printing with FTP. If this works, the problem is the LPD
daemon on your UNIX host. Reconfigure the remote printer and the
LPD daemon. Check the following points.
• The remote host name is the name of the LevelOne Printer

Server.

• The remote printer name is the logical printer name on the

LevelOne Printer Server (e.g. L1).

• If your UNIX asks for the LPD type, be sure to identify the

service type as BSD.

Problem No. 8

I can’t print using PSfilter,

Solution No. 8

Run PSfilter directly with the command:

PSfilter -D P_name -v <file_name&

Where:

P_name is the LevelOne Printer Server’s name
file_name is the file you wish to print.

If this fails, check for an error log file (e.g. PSErrLog XXXXX) in
the /tmp directory. If there is not an error log file, recompile
PSfilter.
Also, check the Troubleshooting section of the Psfilter .TXT file
for your system.

Problem No. 9

The “String Before Job” and/or “String After Job” settings in
the Logical Printers don’t work properly

Solution No. 9

• Check the length of the control strings. No string can exceed

15 characters.

• Check that the control strings are in HEX.