SPECIFICATIONS: Model L20 BF-2

PAGE 27

Flue Size

4” - Top Vent


Height Overall

29”

Height to Flue
Outlet

28

¾”


Width 23”


Depth

15”


Fuel

Natural Gas (standard)

(or) LP Gas (convertible).

Gas inlet 3/8” NPT-Male / Flex Line

(or) remove flex, 3/8” NPT–Female Flare.


Performance

Variable Flame Control.

Features High

Efficiency Heat Exchanger.

Natural Convection & Radiant Heat.

Standing Pilot / Operates During Power

Outages. Remote Control & Wall

Thermostat

Capable.


Technical

Honeywell Combination Gas Control

Features

Valve, Millivolt - VS8520E. Safety Shut

Down Sensor (Spill Switch).

Pan Burner with Tuned Ports.

Radiant & Fan Assisted Convection

Heat.


Safety Test

Tested and certified by CSA to ANSI standards.
Z21.88a-2003

• CSA 2.33a - M98-2003. Vented

Gas Fireplace Heater


Heat Input

17,000 to 26,000 BTU’s (Nat. Gas)

17,000 to 24,000 BTU’s (Propane)


Ship Weight

185 lb.’s


Dimensions shown are approximations only (+ / - ¼”)

Top View

Side View

SPECIFICATIONS

GAS TYPE

NATURAL GAS

PROPANE (LP)

CLEARANCES TO COMBUSTIBLES

Orifice Size

#40 -.098

#53-.0595”

Back Wall Min.

2 In. / 51 mm

Minimum Supply Pressure

4.5” WC

10.5” WC

Side Wall Min.

12 In. / 305 mm

Maximum Supply Pressure

10.5” WC

13.0” WC

Corner (45

° angle)s

HIGH SETTING

stove corner to wall, min.

2 In. / 51 mm

Manifold Pressure

3.5” WC

10.0” WC

Ceiling Height Minimum

65 In. / 1651 mm

Input BTU/HR

26,000

24,000

Alcove Min. Height

65 In. / 1651 mm

LOW SETTING

Alcove Min. width

47 In. / 1194 mm

Mainfold Pressure

1.8” WC

6.6” WC

Alcove - Max. Depth into

Input BTU / HR

17,000

17,000

stove face to alcove opening

24 In. / 610 mm

♦ Altitude - U.S.A. 0-4,500 Ft. (0-1372M) No derating
♦ Altitude - Canada 0-4,500 Ft. (0-1372M) No derating
For installation higher than altitudes shown above, reorifice per Gas Codes.

* With the orifice, manifold pressure and input ratings shown
above.

This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must be field conversed using