It is imperative that the control compart-
ment, burners and circulating air passage
ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les
instructions d'installation et d'utilisation
qui accompagnent l'appareil.

GENERAL INFORMATION

Installation, repair and annual service in-
spection should be performed by a qualifi ed
service technician.

Provide adequate clearances around air openings
and adequate accessibility clearance for service
and proper operation.

Never obstruct the front openings of the
appliance.

Due to high temperatures of this appliance
adequate clearances need to be maintained from
furniture and draperies and other combustibles.
Locate furniture and window coverings accord-
ingly.

The recommended clearance zone from

the front of the appliance to combustibles is 36
inches (914 mm). Maintain all other clearances
as outlined in the Installation Manual.

These fi replaces are designed as supplemen-
tal heaters. Therefore, it is advisable to have
an alternate heat source when installed in a
dwelling.

Input of millivolt model is variable. The rates
are shown in the following table:

This appliance complies with National
Safety Standards and is tested and listed
by OMNI-Test Laboratories Inc.; Beaverton,
Oregon (Report No. 116-F-15-5) to ANSI
Z21.88-2002 (in Canada, CSA-2.33-2002),
and CAN/CGA-2.17-M91 in both USA and
Canada, as vented gas heaters.

Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1. (In Canada, the current
CAN-1 B149 installation code.) Electrical
wiring must comply with the National Elec-
trical Code ANSI/ NFPA 70 - latest edition.
In Canada, the current CSA C22-1 Canadian
Electrical Code - latest edition.

TABLE OF CONTENTS

Introduction ......................................Page 2

General Information ..........................Page 2

Burn-In Period ..................................Page 3

Lighting Millivolt Appliances .............Page 3

Gas Controls .....................................Page 3

Control Compartment Access ...........Page 4

Operation & Care of Your Appliance ..Page 4

Maintenance Procedures ...................Page 4

Maintenance Schedule ......................Page 6

Front Glass Door Assembly,

Removal and Installation .................Page 7

Burner Adjustments ..........................Page 7

Flame Appearance and Sooting .........Page 7

Log Placement Instructions ..............Page 8

Millivolt Appliance Checkout .............Page 11

Blower Operation ..............................Page 11

Fireplace Requirements .....................Page 11

Wiring Diagrams ...............................Page 11

Warranty Information ........................Page 12

Accessory Components ....................Page 12

Lighting Instructions – Millivolt ........Page 15

Replacement Parts List .....................Page 17

Troubleshooting Guide ......................Page 19

INTRODUCTION

The Insert model covered in this manual is
a B-Vent gas heater designed for residential
application for installation into an existing
masonry or factory built solid-fuel fi replace
using 4" diameter, UL1777 listed aluminum
liner for the exhaust. The vent must be routed
through the existing fi replace fl ue system to the
vent termination.

This millavolt appliance is designed to operate
on either natural or propane gas.
A millivolt
gas control valve with piezo ignition system
provides safe, effi cient operation. External
electrical power is required to operate the air
circulation blower.

Millivolt Models with

MAnnually-Modulated Gas Valves

Nat. Gas

Propane

Model No.

Input Rate

(BTU/HR)

Input Rate

(BTU/HR)

EBVI25

17,000 to

25,000

19,500 to

25,000

EBVI30

21,500 to

30,000

22,000 to

28,000

Table 1

WARNING

Do not attempt to alter or modify
the construction of the appliance
or its components. Any modi-
fi cation or alteration may void
the warranty, certifi cation and
listings of this unit.

WARNING

Improper installation, adjust-
ment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualifi ed installer, service
agency or the gas supplier.

WARNING

These fireplace Inserts are
vented heaters. Do not burn
wood or other material in these
appliances.

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-
FACTURED BY LENNOX HEARTH PRODUCTS.

When you purchased your new gas-fi red heater, you joined the ranks of thousands of

individuals whose answer to their home heating needs refl ects their concern for effi ciency
and our environment. We extend our continued support to help you achieve the maximum
benefi t and enjoyment available from your new gas-fi red heater. It is our goal at Lennox
Hearth Products to provide you, our valued customer, with an appliance that will ensure
years of trouble-free warmth and pleasure.

Thank you for selecting a Lennox Hearth Products gas-fi red heater as the answer to

your home heating needs.

Sincerely,
All of us at Lennox Hearth Products