Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs

and Controls

Qualifi ed Service Technician

Inspect valve and ensure it is properly operating. Check piping

for leaks. Vacuum the control compartment, fi replace logs and

burner area.

Check Flame Patterns and Flame

Height

Qualifi ed Service Technician

Refer to Figure 13 on Page 7 and verify the fl ame pattern

and height displayed by the appliance conforms to the picture.

Flames must not impinge on the logs.

Inspecting/Cleaning Pilot and Burner

Qualifi ed Service Technician

Refer to Figure 13 on Page 7 and Figure 25 on Page 11.

Remove any surface build-up on pilot and burner assembly.

Wipe the pilot nozzles, ignitor/fl ame rod and hood. Ensure the

pilot fl ame engulfs the fl ame sensor as shown.

Checking Vent System

Qualifi ed Service Technician

Inspect the vent system at the top and at the base (within the

fi rebox) for signs of blockage or obstruction. Look for any signs

of dislocation of the vent components.

Appliance Checkout

Qualifi ed Service Technician

Perform the appropriate appliance checkout procedure detailed

in this manual.

Replacing Rockwool Ember Materials

Homeowner/Qualifi ed Services Techni-

cian

Remove old ember materials and vacuum the rockwool place-

ment area. Place new rockwool as described on Page 10 (see

Figure 23).

Periodically (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Homeowner

Carefully remove logs, rockwool and and vermiculite. Vacuum out

interior of the fi rebox. Clean fi rebox walls and log grate. Replace

logs, Rockwool and vermiculite as detailed in this manual.

Check Flame Patterns and Flame

Height

Homeowner

Refer to Figure 13 on Page 7 and verify the fl ame pattern and

height displayed by the appliance conforms to the picture. Flames

must not impinge on the logs.

Checking Vent System

Homeowner

Inspect the vent system at the top and at the base (within the

fi rebox) for signs of blockage or obstruction. Look for any signs

of dislocation of the vent components.

Cleaning Front Door Window

Homeowner

Clean as necessary following the directions provided in this

manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE

HOT.

Annually (Before the onset of the Burning Season)