2

Requirements For Maximum Output

In order to utilize the maximum output capability of

the machine, a branch circuit capable of 25 amps at

120 volts, 60 Hertz is required.

A-2

INSTALLATION

POWER MIG (140, 180 MODELS)

A-2

TECHNICAL SPECIFICATIONS 180 Amp units

(K2668-1 180C)

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

Standard Voltage/Frequency

Input Current

240 V 50 Hz

I

1 max

20 Amps

I

1 eff

10.7 Amps

Voltage/Duty Cycle

Current

Voltage at Rated Amperes

240 V 25%

130 Amps

20

Welding Current Range

Open Circuit Voltage

Wire Speed Range

30 - 180 Amps

34 V

50 - 500 in/min.

1.3 - 12.7 ( m/min.)

Input Voltage/Frequency Fuse or Breaker Size

1

Input Amps Power Cord

240 V 50 Hz

40 Amp Super Lag

20 15 Amp, 240 V,

Three Pin Plug

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

14.0 in

10.15 in

18.6 in

66 Ibs

357 mm

258 mm

472 mm

30 kg

PHYSICAL DIMENSIONS

1

If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.