Operation, Warning, B. install shielding gas – Lincoln Electric POWER MIG 180 User Manual

Page 22: Shielding gas

Advertising
background image

B-9

OPERATION

B-9

POWER MIG (140, 180 MODELS)

B. INSTALL SHIELDING GAS

MIG welding requires an appropriate bottle of shielding

gas. For mild steel either a cylinder bottle of Ar/CO

2

or

100% CO

2

can be used refer to the following instruc-

tions to properly connect shielding gas to the machine.

CYLINDER may explode if dam-

aged. Keep cylinder upright and

chained to support
• Keep cylinder away from areas

where it may be damaged.

• Never lift welder with cylinder

attached.

• Never allow welding electrode to

touch cylinder.

• Keep cylinder away from welding

or other live electrical circuits.

-----------------------------------------------------------------------

WARNING

75/25

FEMALE END

MALE END

CO

S19298

REGULATOR

ADAPTER

PLASTIC

WASHER

MIXES

100%

2

3. Attach the flow regulator to the cylinder valve and

tighten the union nut securely with a wrench.

NOTE: If connecting to 100% CO

2

cylinder, a CO

2

regulator adapter is required. Purchase separately

S19298 CO

2

adapter be sure to install plastic washer

included in the fitting on the bottle side.(See Figure

B.13 )

4. Refer to Figure B.13. Attach one end of inlet gas hose

to the outlet fitting of the flow regulator and tighten the

union nut securely with a wrench. Connect the other

end to the machine Solenoid Inlet Fitting (5/8-18

female threads — for CGA — 032 fitting). Make cer-

tain the gas hose is not kinked or twisted.

FIGURE B.13

BUILDUP OF SHIELDING GAS may

harm health or kill.
• Shut off shielding gas supply

when not in use.

1. Secure the cylinder to a wall or other stationary

support to prevent the cylinder from falling over.

Insulate the cylinder from the work circuit and earth

ground. Refer to Figure B.13.

2. With the cylinder securely installed, remove the

cylinder cap. Stand to one side away from the out-

let and open the cylinder valve very slightly for an

instant. This blows away any dust or dirt which may

have accumulated in the valve outlet.

BE SURE TO KEEP YOUR FACE AWAY FROM

THE VALVE OUTLET WHEN “CRACKING” THE

VALVE. Never stand directly in front of or behind

the flow regulator when opening the cylinder

valve. Always stand to one side.

------------------------------------------------------------------------

WARNING

WARNING

SHIELDING GAS

1. For CO

2

, open the cylinder very slowly. For argon-

mixed gas, open cylinder valve slowly a fraction of a

turn. When the cylinder pressure gauge pointer stops

moving, open the valve fully.

2. Set gas flow rate for 30 to 40 cubic feet per hour (14

to 18 I/min.) under normal conditions, increase to as

high as 40 to 50 CFH (18 to 23.5 I/min.) under drafty

(slightly windy) conditions.

3. Keep the cylinder valve closed, except when using

the machine.