Alphabetical list of diagnostic aids, Auto clean, Auto clean delay – Lexmark 4039-1XX User Manual

Page 48: Auto clean frequency, Auto clean auto clean delay auto clean frequency

Advertising
background image

34

Service Manual

4039-1XX

Alphabetical List of Diagnostic Aids

Auto Clean

Auto Clean needs to be turned on if there is an unacceptable
amount of toner being deposited on the back of the page. When
Auto Clean is on, after printing the number of pages specified in
Auto Clean Frequency, the printer pauses the number of seconds
specified in Auto Clean Delay. This pause minimizes the toner
accumulating on the fuser cleaner.

1. Enter Diagnostics mode.

2. Select [Auto Clean].

3. Select [On] or [Off].

4. Press Return to return to Diagnostics mode main menu.

Auto Clean Delay

This can be set from 1 to 60 seconds with a default of 1. Auto Clean
Delay does not appear on the menu unless Auto Clean is on.

1. Enter Diagnostics mode.

2. Select [Auto Clean Delay].

3. Select [+] or [-] to display the delay desired.

4. Select [SAVE].

5. Press Return to return to Diagnostics mode main menu.

Auto Clean Frequency

This can be set from 10 to 255 pages with a default of 50. Auto
Clean Delay does not appear on the menu unless Auto Clean is on.

1. Enter Diagnostics mode.

2. Select [Auto Clean Frequency].

3. Select [+] or [-] to display the frequency desired.

4. Select [SAVE].

5. Press Return to return to Diagnostics mode main menu.

Advertising