brush to remove dirt trapped in treadbelt surface. A damp (not wet!) sponge can be used to
finish the cleaning process.

Institutional drive motor maintenance

Yearly Institutional Maintenance: Replace the Drive Motor Brushes.
Failure to do so will result in premature Drive Motor failure.

1. Unplug Treadmill.
2. Remove Motor Brush caps (2).
3. Remove Motor Brushes and inspect. They should be replaced if 1/4 inch or less. Inspect

motor Commutator for wear (Black-scoring present on copper segments) Try to dress out
(clean up) Commutator with a Commutator stone or emery cloth.

4. When you reinstall motor brushes make sure the brush does not bind up in its holder. The

motor brush must move freely the full length with zero resistance. If resistance is present you
must carefully dress out the brush until the correct tolerance is achieved.

Motor brushes should be checked every 6 months on institutional treadmills and after 6 years on
home units.

SERVICE CHECK-LIST

Check Treadbelt tension and tracking
Wipe underneath treadbelt
Lubricate Treadbelt
Check drive belt tension
Check motor brushes and commutator
Vacuum under motor hood
Vacuum around and under treadmill