LRA Linear Residential Actuator Installation Guide

- 8 -

228158 Revision X13 2-3-2009

Indicator Descriptions

INDICATOR DEFINITION

INDICATION WHEN LIT

DURING NORMAL OPERATION

INDICATION WHEN LIT

DURING PROGRAMMING

OPERATION

PROGRAMMING

24 VOLT INPUT
POWER

LOW VOLTAGE AC POWER IS PRESENT

24 VOLT DC
ACCY POWER

LOW VOLTAGE DC POWER IS PRESENT

OPEN

OPEN SIGNAL PRESENT FROM THE INTERNAL
RECEIVER OR AN EXTERNAL DEVICE
CONNECTED TO THE OPEN INPUT TERMINAL

CLOSE

CLOSE SIGNAL IS PRESENT FROM A DEVICE
CONNECTED TO THE CLOSE INPUT TERMINAL

STOP

STOP INPUT TERMINAL IS OPEN AND
NOT CONNECTED TO COMMON

PROGRAM

CONTROLLER IS IN PROGRAMMING MODE

REVERSE

DELAY SET

SIGNAL FROM REVERSING DEVICE IS PRESENT

SET REVERSE DELAY TIME

LOCKOUT

ALARM SET

CONTROLS AND OPERATOR ARE LOCKED OUT
BECAUSE OF EXISTING TROUBLE CONDITION

SET RUN ALARM AND PRE-START ALARM

RADIO

LEARN

BUILT-IN RECEIVER IS DETECTING A RADIO
SIGNAL FROM A REMOTE CONTROL

TRANSMITTERS CAN BE ENTERED INTO
MEMORY (UP TO 40 TRANSMITTERS)

OPEN CURRENT

SET

MOTOR CURRENT HAS EXCEEDED THE
OPEN CURRENT SETTING WHILE OPENING

SET MAXIMUM OPEN CURRENT

OPEN OBSTR

MGT 2 SET

OPEN OBSTRUCTION TERMINAL CONNECTED
TO COMMON BY BEAM OR SAFETY EDGE, OR
SIGNAL FROM MGT OBSTACLE TRANSMITTER

SET MGT #2 FUNCTION

OPEN RELAY

OPEN RELAY IS ACTIVATED

OPEN LIMIT

BRAKE DELAY

OPEN LIMIT SWITCH IS ACTIVATED

CLOSE CURRENT

SET

MOTOR CURRENT HAS EXCEEDED THE
CLOSE CURRENT SETTING WHILE CLOSING

SET MAXIMUM CLOSE CURRENT

CLOSE OBSTR

MGT 1 SET

CLOSE OBSTRUCTION TERMINAL CONNECTED
TO COMMON BY BEAM OR SAFETY EDGE, OR
SIGNAL FROM MGT OBSTACLE TRANSMITTER

SET MGT #1 FUNCTION

CLOSE RELAY

AUTO CLOSE SET

CLOSE RELAY IS ACTIVATED

SET AUTO-CLOSE TIME

CLOSE LIMIT

CLOSE LIMIT SWITCH IS ACTIVATED

SINGLE

SET

SINGLE TERMINAL CONNECTED TO COMMON
BY AN EXTERNAL PUSHBUTTON OR RADIO

SET SINGLE BUTTON INPUT FUNCTION

MAX RUN

SET

MAXIMUM RUN TIMER HAS BEEN EXCEEDED

SET MAXIMUM RUN TIME

COMM LINK

SET

DUAL OPERATOR CONNECTION DETECTED,
BLINKS IF CONNECTION HAS FAILED

MAINT ALERT

SET

MAINTENANCE IS REQUIRED ON OPERATOR

SET MAINTENANCE ALERT CYCLE COUNT

"RL" LEFT OR RIGHT

HAND OPERATION

"PM" SINGLE OR

DUAL GATE

"AC" AUTO CLOSE

TIMER

"RP" RUN ALARM

PRE-START ALARM

"OC" MAXIMUM OPEN

CURRENT

"CC" MAXIMUM CLOSE

CURRENT

"AD"

ADVANCED
PROGRAMMING

"RT" MAXIMUM

RUN TIMER

"SB"

SINGLE BUTTON

INPUT SETUP

"SM" STAGGER

MODE

"ST" STAGGER

TIME

"AR" AUXILIARY

RELAY MODE

"RD" REVERSE

DELAY TIME

"LP"

LOW POWER

MODE

POWER

FAILURE MODE

"FS"

"SS" SOFT START/STOP

DURATION

"CT" RESET CYCLE

COUNT

"MA"

MAINTENANCE ALERT
TRIGGER

"MT" MID-TRAVEL

STOP POSITION

"RA"

RADIO

ENABLE

"TL" LEARN

TRANSMITTERS

"TD"

DELETE

TRANSMITTERS

"ML"

LEARN MGT

TRANSMITTERS

"MD"

ERASE MGT

TRANSMITTERS

"CL"

RESET TO

FACTORY DEFAULTS

APEX FUNCTION DISPLAY INDICATIONS

MOTOR TYPE

SELECTION

"MO"