LRA Linear Residential Actuator Installation Guide

- 15 -

228158 Revision X13 2-3-2009

Advanced Controller Programming (Cont.)

Soft Start/Stop Duration

This function causes the operator to start and stop the DC motor slowly
reducing gate wear and tear (at the full open or closed positions only).
The factory default sets the Soft Start/Stop Duration to 3 seconds. The
Soft Start/Stop Duration can be set from 1 to 10 seconds.

NOTE: Changing the Soft Start/Stop Duration will reset the open and
close current setting value to zero. It will be necessary to reprogram
maximum open and close current settings.

Reset Cycle Count

The Controller counts of the number of times the operator has been
activated and can display the count rounded off to the nearest 1000. To
reset the Cycle Count, press and hold the

ENTER button for 2 seconds

while the Cycle Count is displayed.
If the Maintenance Alert has been triggered, resetting the Cycle Count
will also reset the Maintenance Alert indicator.

Maintenance Alert Trigger

The Controller has a

MAINT ALERT indicator that can be programmed to

light when the number of activations exceeds a set number of cycles.
The factory default sets the Maintenance Alert Trigger to 10,000 cycles.
The Maintenance Alert Trigger can be programmed for 5, 10, 15, or 25
thousand cycles.
The Maintenance Cycle Count can be reset independently from the
operator’s absolute Cycle Count.

Mid-travel Stop Position

The Controller can be programmed so the gate will stop at a mid-travel
point instead of fully opening. This can be useful in installations where a
large gate, that takes a long time to open and close fully, only needs to
be opened partway to allow traffic to pass.
The factory default sets the Controller for full open operation. Alternately,
the Controller can be programmed to open for 1 to 99 seconds then stop,
before reaching the open limit.
When a Mid-travel Stop Position time has been programmed, the gate
will

still fully open if the Fire Department input is triggered, if the OPEN

button is held down beyond the Mid-travel Stop Position, or a close
obstruction or reverse loop input is triggered.

NOTE: The Mid-travel Stop feature is disabled when dual gate
operation is enabled for paired units.

Motor Type Selection

The factory sets the default for the Controller to match the type of motor in
the operator.

When the Controller is used with the Model LRA Linear

Residential Actuator leave this setting at the factory default.

FUNCTION

SETS THIS MAINTENANCE ALERT TRIGGER

FOR 5, 10, 15, OR 25 THOUSAND CYCLES

DISABLES THE MAINENANCE ALERT
FUNCTION

RESETS THE MAINTENANCE ALERT

INDICATOR AND SETS THE MAINTENANCE
ALERT COUNT TO ZERO

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MAINTENANCE

ALERT TRIGGER

"MA"

FUNCTION

SET LENGTH OF OPENING TIME

FROM 1 TO 99 SECONDS

MID-TRAVEL STOP DISABLED

(GATE RUNS FULL TRAVEL)

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MID-TRAVEL

STOP POSITION

"MT"

FUNCTION

DISPLAY SHOWS NUMBER OF OPERATION

CYCLES (OPEN OR CLOSE) ROUNDED TO

THE NEAREST 1000

OPTIONS

NOTE: PRESS ENTER FOR 2 SECONDS

WHILE THE "CT" FUNCTION IS DISPLAYED

TO RESET CYCLE TIMER TO ZERO

RESET CYCLE

COUNT

"CT"

FUNCTION

MOTOR TYPE

SELECTION

"MO"

LEAVE THE CONTROLLER SET FOR

DC MOTOR OPERATION WITH

SOFT START/STOP FOR

ALL MODEL LRA INSTALLATIONS

FUNCTION

SET SOFT START DURATION TIME

FROM 1 TO 10 SECONDS

SOFT START DISABLED

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

SOFT START/STOP

DURATION

"SS"

DC MODELS

ONLY