Using Monitor Mode

UDS10/UDS100 User Guide

44

Using Monitor Mode Commands

The following commands are available in Monitor Mode. Many commands have an IP
address as an optional parameter (x.x.x.x). If the IP address is given, the command is
applied to another unit with that IP address. If no IP address is given, the command is
executed locally.

Note:

All commands must be in capital letters, with blank spaces between

the settings.

Table 7-1. Monitor Mode Commands

Command

Command Name

Function

SF x.x.x.x

Send Firmware

Sends firmware to unit with IP address x.x.x.x.

VS x.x.x.x

Version

Queries software header record (16-byte) of unit with
IP address x.x.x.x.

GC x.x.x.x

Get Configuration

Gets configuration of unit with IP address x.x.x.x as
hex records.

SC x.x.x.x

Send Configuration

Sets configuration of unit with IP address x.x.x.x from
hex records.

PI x.x.x.x

Ping

Pings unit with IP address x.x.x.x to check device
status.

AT

ARP Table

Shows the unit’s ARP table entries.

TT

TCP Connection Table

Shows all incoming and outgoing TCP connections.

NC

Network Connection

Shows the unit’s IP configuration.

RS

Reset

Resets the unit’s power.

QU

Quit

Exits diagnostics mode.

G0, G1...GE,
GF

Get configuration from memory page

Gets a memory page of configuration information from
the device.

S0, S1... SE,
SF

Set configuration to memory page

Sets a memory page of configuration information on
the device.

Entering any of the commands listed above generates one of the following command
response codes:

Table 7-2. Command Response Codes

Response Meaning

0>

OK; no error

1>

No answer from remote device

2>

Cannot reach remote device or no answer

8> Wrong

parameter(s)

9> Invalid

command