Factory default settings, Channel 1 configuration defaults, Expert settings defaults – Lantronix UDS100 User Manual

Page 38: Security settings defaults, Exit configuration mode

Advertising
background image

Configuring the UDS Using Telnet or the Serial Port

UDS10/UDS100 User Guide

38

Factory Default Settings

Select 7 to reset the unit’s serial port to the factory default settings. The server
configurations (IP address information) remain unchanged. The specific settings that
this option changes are in the following list:

Channel 1 Configuration Defaults

Baudrate 9600

I/F Mode

4C (1 stop bit, no parity, 8 bit, RS-232C)

Own TCP port number

10001

Connect Mode

C0 (always accept incoming connection; no active
connection startup)

Hostlist retry counter

3

Hostlist retry timeout

250 (msec)

Start character

0x0D (CR)

All other settings

0

Expert Settings Defaults

TCP keepalive

45 (seconds)

ARP cache timeout

600 (seconds)

Security Settings Defaults

SNMP Enabled

SNMP community name

public

Telnet setup

Enabled

TFTP download

Enabled

Port 77FEh

Enabled

Web Server

Enabled

ECHO Disabled

Encryption Disabled

Enhanced password

Disabled

Exit Configuration Mode

To exit Setup Mode:

‹

To save all changes and reboot, select 9. All values are stored in nonvolatile
memory.

‹

To exit the configuration mode without saving changes or rebooting, select 8.