Fireplace insert installation, For qualified installers only), Insert with face seal connection – Lopi Answer Wood Stove User Manual

Page 23

Advertising
background image

Fireplace Insert Installation

(for qualified installers only)

23

© Travis Industries

100-01166

4040907

Insert with Direct
Connection (Z.C.
Fireplace)

NOTE:

Direct connections
require installation of an
airtight block-off plate or
damper adapter (see
"Block-off Plate
Installation" on page
21).

Block-off plate or
damper adapter

Stainless steel
chimney connector
must Extend 1' past
the block-off plate.

Combustible Mantle

See the section
"Insert Placement
Requirements" for
minimum clearances
and hearth required.

Surround Panels

NOTE: This installation may be
used with a masonry or zero
clearance fireplace. This
illustration depicts a zero
clearance insert, all requirements
in the section "Zero Clearance
Fireplace Requirements" must be
fulfilled prior to installation.

Z.C. (Metal) firebox

Optional

Telescoping Legs

No modification to the firebox
of the z.c. fireplace is allowed.

Damper must
be removed

Insert with Face
Seal Connection

NOTE:

Face seal connections
require installation of the
surround panels and
insulation (see the
"Surround Panel
Installation" on page
45).

Remove damper

or wire it open

Airtight Insulated

Clean-Out

Combustible Mantle

NOTE: This installation may be

used with a masonry fireplace

only. The requirements in the

section "Masonry Fireplace

Requirements" must be fulfilled

prior to installation.

Flue

Liner

See the section "Insert

Placement Requirements"

for minimum clearances

and hearth required.

Surround Panels with

insulation (see "Surround

Panels" installation

instructions in the back of

the manual)

NOTE: It is

recommended your

chimney have a

minimum 28 and a

maximum of 144

square inch cross-

sectional area to use a

face seal connection,

otherwise your

chimney maynot have

sufficient draw for the

fireplace insert to

operate correctly.