Troubleshooting, Troubleshooting guide – Lincoln Electric IDEALARC SP-255 User Manual

Page 41

Advertising
background image

E-5

TROUBLESHOOTING

IDEALARC SP-255

Observe Safety Guidelines
detailed in the beginning of this manual.

TROUBLESHOOTING GUIDE

PROBLEMS
(SYMPTOMS)

The SP-255 stops feeding wire
while welding and the MOTOR
OVERLOADED message appears
on the LCD display.

The voltage and/or wire feed speed
are being changed even though the
gun thumbswitch or front panel
arrow keys are not activated.

The LCD display is not readable
even though the backlighting is
functioning.

Error messages or alarm continu-
ously beeps in bursts of three.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check for any restriction in the

wire feeding path.

2. Make sure the correct size con-

tact tip, gun liner and drive rolls
are being used.

1. The thumbswitch circuit in the

gun and cable assembly may be
faulty. Repair or replace.

1. There may have been an inter-

nal system “fault”. Turn input
power off for a few seconds.
Turn power back on and check
for proper machine operation.

2. Check the input voltage. Make

sure the input voltage matches
the nameplate rating and the
reconnect panel configuration.

1. There may be an error in the

system or the keypad entry. See
Explanation of Prompting and
Error Messages in the Operation
section.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
contact your local Lincoln
Authorized Field Service Facility.

FUNCTION PROBLEMS

Advertising