Installation, Technical specifications – idealarc, Sp-255 – Lincoln Electric IDEALARC SP-255 User Manual

Page 9

Advertising
background image

A-1

INSTALLATION

AUG 95 IDEALARC SP-255

75C Copper Wire 75C Copper Wire

in Conduit

in Conduit

Input

Fuse or

Input Ampere

AWG (IEC)

AWG (IEC)

Voltage/

Breaker Size

Rating on

Sizes

Sizes

Frequency

(Super Lag)

Nameplate

For lengths

For lengths

Ground Wire

up to 100 ft.

exceeding 100 ft.

208

60

53

8 (10 mm

2

)

6 (16 mm

2

)

#10 (6 mm

2

)

230

60

50

10 (6 mm

2

)

8 (10 mm

2

)

#10 (6 mm

2

)

460

30

25

14 (2.5 mm

2

)

12 (4 mm

2

)

#10 (6 mm

2

)

575

25

20

14 (2.5 mm

2

)

12 (4 mm

2

)

#10 (6 mm

2

)

TECHNICAL SPECIFICATIONS – IDEALARC

®

SP-255

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

28.2 in

18.8 in

40.1 in

222 Ibs

719 mm

480 mm

1019 mm

101 kg

PHYSICAL DIMENSIONS

-20° C TO 40°C

±40°C

OPERATING TEMPERATURE

STORAGE TEMPERATURE

Standard Voltage/Frequency

Input Current (@ Max Rated Output)

208/230/60 Hz

53/49 Amps

230/460/575 Hz

50/25/20 Amps

Duty Cycle

Amps

Volts at Rated Amperes

35%

250 Amps

26 Volts

60%

200 Amps

28 Volts

100%

145 Amps

26 Volts

Welding Current Range

Maximum Open Circuit Voltage

Wire Speed Range

30-250 Amps

40 Volts

50-600 IMP (1.27-15.2 m/min)