Lenovo RD120 User Manual

Page 60

Advertising
background image

1

RAID

controller

4

Battery

mounting

tabs

2

Battery

cable

5

Battery

mounting

clips

3

Battery

6

Battery

cable

connector

9.

Turn

the

new

ServeRAID-8k

SAS

controller

so

that

the

keys

on

the

bottom

edge

align

correctly

with

the

connector.

10.

Firmly

press

the

ServeRAID-8k

SAS

controller

straight

down

into

the

connector

by

applying

pressure

on

both

ends

of

the

controller

simultaneously.

The

retaining

clips

snap

into

the

locked

position

when

the

controller

is

firmly

seated

in

the

connector.

Note:

If

there

is

a

gap

between

the

controller

and

the

retaining

clips,

the

controller

has

not

been

correctly

installed.

In

this

case,

open

the

retaining

clips

and

remove

the

controller;

then,

reinsert

the

controller.

11.

Remove

the

battery

from

the

ServeRAID-8k

SAS

Controller

package.

12.

Slide

the

battery

mounting

tabs

into

the

battery

mounting

clips

on

the

server

wall

that

is

next

to

the

ServeRAID

SAS

controller

connector.

13.

Connect

the

battery

to

the

ServeRAID-8k

SAS

Controller.

14.

Replace

the

air

baffle

over

the

DIMMs

(see

“Installing

the

DIMM

air

baffle”

on

page

38).

15.

Replace

the

riser-card

assembly

(see

“Installing

the

riser-card

assembly”

on

page

34).

If

you

have

other

optional

devices

to

install

or

remove,

do

so

now.

Otherwise,

go

to

“Completing

the

installation”

on

page

74.

Notes:

1.

When

you

restart

the

server

for

the

first

time

after

you

install

a

ServeRAID-8k

SAS

controller,

the

monitor

screen

remains

blank

while

the

controller

initializes

46

ThinkServer

RD120

Types

6444,

6445,

6446,

and

6447:

User

Guide