Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply

and

to

install

and

remove

a

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply

for

installation

instructions.

1.

Read

the

safety

information

that

begins

on

page

v

and

“Installation

guidelines”

on

page

29.

2.

Remove

the

power-supply

filler

panel

from

the

empty

power-supply

bay

by

pinching

the

side

clip

and

pulling

the

power-supply

filler

panel

from

the

bay.

Save

the

power-supply

filler

panel

in

case

you

remove

the

power

supply

at

a

later

time.

Important:

During

normal

operation,

each

power-supply

bay

must

contain

either

a

power

supply

or

power-supply

filler

panel

for

proper

cooling.

3.

Slide

the

ac

power

supply

into

the

bay

until

the

retention

latch

clicks

into

place.

4.

Remove

the

server

cover

and

install

the

five

cooling

fans

that

came

with

the

power-supply

(see

“Installing

a

fan”

on

page

68).

Important:

When

power

supply

1

is

installed,

the

five

fans

for

power

supply

1

occupy

the

rear

row

only

(fans

3,

4,

8,

9,

and

10);

when

both

power

supplies

are

installed,

all

10

fans

must

be

installed.

See

the

fan

numbers

on

the

microprocessor

air

baffle,

or

see

the

illustration

in

“Removing

a

fan”

on

page

69.

5.

Connect

the

power

cord

for

the

new

ac

power

supply

to

the

power-cord

connector

on

the

power

supply.

The

following

illustration

shows

the

ac

power-supply

connectors

on

the

back

of

the

server.

1

Power

cord

connectors

2

Power

supply

2

3

Power

supply

1

6.

Route

the

power

cord

through

the

power-supply

handle

and

through

any

cable

clamps

on

the

rear

of

the

server

to

prevent

the

power

cord

from

being

accidentally

pulled

out

when

you

slide

the

server

in

and

out

of

the

rack.

7.

Connect

the

power

cord

to

a

properly

grounded

electrical

outlet.

8.

Make

sure

that

the

dc

power

LED

and

ac

power

LED

on

the

power

supply

are

lit,

indicating

that

the

power

supply

is

operating

correctly.

If

you

have

other

optional

devices

to

install

or

remove,

do

so

now.

Otherwise,

go

to

“Completing

the

installation”

on

page

74.

Chapter

2.

Installing

optional

devices

67