A-1

INSTALLATION

V160-T

A-1

Input Circuit

115V (20A Plug and Branch)

115V (30A Branch)

230V (30A Branch)

230V (30A Branch)

Maximum Open Circuit Voltage

48 Volts Max.

Duty Cycle

100%

35%

100%

Output Current Range

5-160 Amps

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

Height

Width

Depth

Weight

12.6 in.

7.9 in.

16.9 in.

Approx. 24.2lbs.

320 mm

200 mm

430 mm

11 kgs.

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-50°C to +85°C

RECOMMENDED INPUT WIRE AND FUSE SIzES FOR MAXIMUM RATED OUTPUT

INPUT VOLTAGE /
FREQUENCY (Hz)

230/50/60

MAXIMUM TIME-DELAY CIRCUIT

bREAKER OR FUSE SIzE (AMPS)

30

TYPE S, SO ST, STO, OR EXTRA

HARD USAGE INPUT CORD AWG

#12

TECHNICAL SPECIFICATIONS - V160-T

Input Voltages / 50 /60 Hz.

115 V (20 A Plug and branch)

115 V (30 A branch)

230 V

Max. Input Current at rated Output

20 A
25 A
34 A

Output Amps

60 (Stick)

90 (TIG)

80 (Stick)
110 (TIG)

160 (Stick)

160 (TIG)

130 (Stick)

130 (TIG)

Output Volts

22.4
13.6

23.2
14.4

26.4
16.4

25.2
15.2

Type of Output

DC