Optional remote keypad, Optional keyswitch – Linear RE-2 User Manual

Page 12

Advertising
background image

10

OPTIONAL REMOTE KEYPAD

The optional Model AM-KP remote keypad can be used with the
RE-2 entry system. A typical application for the remote keypad
would be to control a second door or gate. Entry codes are the only
method of access allowed at a remote keypad. The default system
setting will cause the remote keypad to activate Relay #2.

1. Mount the AM-KP keypad onto a pedestal or to a wall.
2. Route 6-conductor cable from the RE-2 to the AM-KP.

• For wire runs up to 300 feet use 24 AWG Belden Type 9931 or

equivalent.

• For wire runs up to 600 feet use 20 AWG Weico Type 9405 or

equivalent.

3. Set

the

DEVICE ADDRESS rotary switch in the AM-KP to match the

remote keypad address in the RE-2 (default = 3).

4. Connect the 6-conductor cable as shown in Figure 19.
5. Secure and lock the AM-KP to its mounting plate.

OPTIONAL KEYSWITCH

The RE-2 case is designed to accept the following keyswitch:

KNOX COMPANY MODEL 3501

KNOX COMPANY

800-552-5669

www.knoxbox.com

Keyswitch Installation

1. Remove the screw and washer that retain the keyswitch hole access

plate (see Figure 20).

2. Hold the lock cover and plastic spacer in place on the RE-2 case.

Secure the assembly with four screws, lock washers, and nuts. Slide
the keyswitch into the hole, oriented as shown (see Figure 21).
Secure the keyswitch with the large switch nut.

3. Plug the two keyswitch snap-on wire leads (supplied with the switch)

onto the keyswitch COM and N.O. pins (see Figure 22).

4. Connect one keyswitch wire to the RE-2 OPEN #1 terminal. Connect

the other keyswitch wire to the RE-2 COMMON terminal (see
Figure 23).

SET SWITCH
TO NUMBER 3

Figure 18. Setting the Keypad Device Address

OPEN #1

KEYPAD GND

KEYPAD DAT 1

KEYPAD DAT 0

KEYPAD PWR

TRANSFORMER

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

COMMON

KEYPAD CLK

KEYPAD DVAL

OPEN #2

RE-2

TERMINALS

SENSE #2

PWR

GND

DAT1

DAT0

DVAL

CLK

AM-KP

REMOTE

KEYPAD

USE BELDEN 9931 (24 AWG) CABLE FOR RUNS UP TO 300 FEET

USE WEICO 9405 (20 AWG) CABLE FOR RUNS UP TO 500 FEET

Figure 19. Remote Keypad Wiring

REMOVE SCREW
AND WASHER

REMOVE
COVER
PLATE

Figure 20. Removing the Keyswitch Hole Access Plate

INSTALL COVER
PLATE AND SPACER
WITH FOUR SCREWS,
LOCKNUTS, & NUTS

SPACER

COVER
PLATE
ASSEMBLY

INSERT KEYSWITCH
INTO HOLE WITH
KEYSLOT ORIENTED
AS SHOWN

Figure 21. Keyswitch Wire Connections

ACCESS

KEYSWITCH

OPEN #1

KEYPAD DAT 1

KEYPAD DAT 0

SENSE #1

COMMON

KEYPAD CLK

KEYPAD DVAL

OPEN #2

RE-2

TERMINALS

SENSE #2

NOTE: THE KEYSWITCH CAN BE WIRED TO
THE OPEN #2 TERMINAL TO CONTROL
A SECOND GATE OR DOOR

Figure 23. Keyswitch Wiring

COM

N.O.

KEYSWITCH
CONNECTION
PINS

CONNECT SWITCH WIRES
TO COM AND N.O. SWITCH PINS

SWITCH SECURED
WITH LARGE NUT

Figure 22. Keyswitch Wire Connections