RESIDENT PROGRAMMING QUICK REFERENCE

Some of the programming PPN’s may be commonly used by the
resident. Following are quick references to the keystrokes required.

NOTE: The “###” is the default command prefi x. The following example

assumes that the default has not been changed.

To Enter Programming Mode

Press:

Master Code

Master Code = the current 6-digit Master Programming Code

To Exit Programming Mode & Save Changes

Press:

Re-entering a Command After a Mistake

If an incorrect entry, or an incorrect key is pressed during programming, to
clear the keypad:

Press:

Adding a Entry Code

Press:

Code

Code

Relay

Time Zone

Code = The new entry code: 1-999999, depending on code length
Relay = Relay output entry code will activate:
1 = Relay #1 2 = Relay #2 3 = Both Relays
4 = Relay #1 as priority user (no access restrictions)
Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7

Adding a Temporary Entry code

Press:

Code

Code

Relay

Time Zone

Number

Valid From

Valid Thru

Code = The new entry code: 1-999999, depending on code length
Relay = Relay output entry code will activate:
1 = Relay #1 2 = Relay #2 3 = Both Relays
Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7
Number = Number of times (1-255) that the entry code is allowed access
Valid From = First date (MMDDYY) that the entry code is valid
Valid Thru = Last date (MMDDYY) the entry code is valid.

Removing a Single Entry Code

Press:

Code

Code

Code = The entry code to remove.

Suspend or Activate a Single Transmitter

Press:

Facility

ID

Action

Facility = Facility code 1-16 of transmitter (0 = no facility code)
ID = 5-digit ID number of transmitter
Action: 0 = Suspend transmitter; 1 = Re-activate transmitter

Maximum Number of Visitor Rings

Press:

Rings

Rings = 1-15 Rings maximum

Visitor Talk Time Limit

Press:

Limit

Limit = 15-255 Seconds allowed

Call Waiting Feature On/Off

Press:

Call Waiting

Call Waiting: 1 = ON; 2 = OFF

Call Forwarding

Press:

Forwarding

Time Zone

Telephone Number

Extension

Delay

Forwarding: 0 = Call forwarding feature OFF

1 = Call forwarding feature ON at all times

2 = Call forwarding feature ON (scheduled by Time Zone)

Time Zone = 1-7 (Call forwarding feature active during this Time Zone)
Telephone Number = Up to 11-digit telephone number
Extension = Up to 4-digit telephone extension number
Delay = 1-25 seconds (delay between telephone number and extension)

“Do Not Disturb” Privacy Feature On/Off

Press:

Privacy

Time Zone

Privacy:

0 = Privacy feature OFF

1 = Privacy feature ON (scheduled by Time Zone)

2 = Privacy feature ON at all times

Time Zone = 1-7 (Privacy feature active during this Time Zone)

Automatic Door/Gate Open Time

Press:

Relay

1st Time Zone

2nd Time Zone

Relay:

1 = Relay #1

2 = Relay #2

1st Time Zone = Time Zone 1-7
2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)

Setting Time Zones

Press:

Time Zone Number

Active Days

Start Hour

Start Minute

AM/PM

End Hour

End Minute

AM/PM

Time Zone Number = 1-7
Active Days (Enter up to 8 digits):
1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat; 8 = Holidays
Start Hour = 1-12 Start Minute = 0-59 AM/PM: 0 = AM; 1 = PM
End Hour = 1-12 End Minute = 0-59 AM/PM: 0 = AM; 1 = PM

Setting the Holiday Days

Press:

Holiday Number

Month

Day

Holiday Number = 1-10
Month = 1-12
Day = 1-31

Advertising