ENTRY SYSTEM MOUNTING

Pedestal Mounting

The RE-2 Entry System can be mounted with the Model GNC-1
(curb mount) or Model GNB-1 (burial mount) gooseneck pedestals.

1. Open the RE-2 case by removing the four security screws with the

wrench provided (see Figure 1).

2. Use four security bolts and locking nuts to secure the backplate to the

pedestal (see Figure 2).

Wall Mounting

The RE-2 Entry System can be mounted directly to a wall or fl at
surface.

1. Open the RE-2 case by removing the four security screws with the

wrench provided (see Figure 1).

2. Use the appropriate fasteners to secure the system’s backplate to the

mounting surface. When mounting the system to a concrete wall, use
concrete wedge anchors (see Figure 3).

Recessed Mounting

The RE-2 can be mounted recessed using an accessory trim-ring.
The trim-ring mounts in the wall and the cabinet attaches to the
trim-ring.
Two trim-rings models are available to match the color of the RE-2
case:

• For the RE-2N use trim-ring P/N ACP00915.
• For the RE-2SS use trim-ring P/N ACP00917.

1. Identify the location of any studs in the wall.
2. Cut a 10-1/4” wide by 6-1/4” high rectangular hole between studs at

the mounting location.

3. Install any additional mounting material required to provide surfaces

inside the wall for attaching the trim-ring.

4. Place the trim-ring in the wall hole. Check for level, then attach the

trim-ring with screws into the side tabs.

5. Drill the cabinet’s four self-drill mounting holes the appropriate size for

the hardware.

6. Attach the cabinet to the trim-ring using self-tapping screws.
7. Route the wiring into the cabinet.

Figure 3. Wall Mounting

Figure 2. Pedestal Mounting

REMOVE THE FOUR
SECURITY SCREWS
TO OPEN THE CASE

Figure 1. Opening the RE-2 Case

PEDESTAL

MOUNTING

MOUNT REAR CASE
WITH SECURITY BOLTS
AND LOCKNUTS

PEDESTAL

CAUTION!

BE SURE THE MOUNTING HARDWARE

DOES NOT EXTEND MORE THAN 1"

INSIDE THE REAR COVER OR

ELECTRICAL DAMAGE MAY OCCUR

USE WEDGE ANCHORS
FOR CONCRETE OR
OTHER APPROPRIATE
ANCHORS FOR DIFFERENT
MATERIALS

WALL

MOUNTING

CAUTION!

BE SURE THE MOUNTING HARDWARE

DOES NOT EXTEND MORE THAN 1"

INSIDE THE REAR CASE OR

ELECTRICAL DAMAGE MAY OCCUR

10-1/4"

6-1/4"

MARK HOLE LOCATION

4

INSTALL ANY SPACER
SHIMS TO ALLOW MOUNTING

ATTACH THE TRIM-RING
WITH SCREWS

5

6

DRILL 3/16" HOLES IN
THE CABINET AT THE
PRE-MARKED LOCATIONS

ATTACH THE CABINET TO
THE TRIM-RING WITH
SELF-TAPING SCREWS

DETERMINE LOCATION FOR
THE 10-1/4" x 6-1/4" MOUNTING HOLE

3

CUT MOUNTING HOLE

1

2

RECESSED
MOUNTING

Figure 4. Recessed Mounting