Warnings, Flame color and behavior – Lennox Hearth EPIC40 User Manual

Page 20

Advertising
background image

0

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Flame Color and Behavior

Your stove is designed for maximum heating efficiency.

Therefore, upon lighting of the main burner the flames will

be semitransparent or “bluish.” After 10-20 minutes of

operation, the logs will heat up and the flames will become

a yellow/orange color.

Adjusting the stove to cause the flames to turn orange sooner

may result in poor combustion, sooting and a hazardous

situation. See the drawing to the right showing proper flame

appearance.

When testing for proper operation - If an optional thermo-

stat is installed adjust it to its highest temperature setting.

Visually determine that main burner gas is burning properly:

i.e., no floating, lifting or flashback. Adjust the primary air

shutter(s) as required. Check for proper main burner opera-

tion at both high and low flame.

8. After pilot is lit, turn gas control counter-clockwise to

“ON.” Knob can only be turned “ON” if the knob has popped

out.

9. To turn burner on, turn “ON/OFF” rocker switch to “ON” or

set the thermostat to the desired temperature above room

temperature.

10. Adjust the flame height (and heat output) by turning the flame

height knob clockwise for reduced flame and counter-

clockwise for full flame.

11. Set the blower to the desired air flow after it turns on when the

appliance reaches operating temperature.

TO TURN OFF GAS TO APPLIANCE

1. Turn the “ON/OFF” rocker switch and/or thermostat (if installed)

to “OFF.”

2. Turn off electric power to the appliance if service is to be

performed.

3. Turn gas control knob clockwise to “OFF.” Do not

force.

This appliance needs fresh air for safe operation and must be

installed so there are provisions for adequate combustion and

ventilation air. See Installation and Operation Manual accompa-

nying appliance.

SHUTDOWN PROCEDURE

To turn off the burner, turn the rocker switch to “OFF” or adjust

the thermostat (if installed) to a setting below room temperature.

The pilot will remain lit for future burner ignition. For complete

shutdown, see “TO TURN OFF GAS TO APPLIANCE” above.

No Blue Flame

Center

Soot at

Flame Tip

Dark Orange

Flame

IMPROPERLY

BURNING FLAME

Soot above

Flame Tip

No Soot at

Flame Tip

PROPERLY

BURNING FLAME

Semi-Transparent

Yellow Flame

Blue Flame

Center

Ports on Pan

Burner Assembly

Burner Flame Appearance

Figure 30

SIT Millivolt Gas Valve

Gas Control Knob

(Pilot / On / Off)

Flame Height Control

Knob (HI/LO)

ON

OFF

PIL

OT

HI

LOW












GAS CONTROL

ON/OFF

FLAME HEIGHT

Control Panel

Figure 29

WARNINGS

Improper installation, adjustment, alteration,

service or maintenance can cause injury or

property damage. For assistance or additional

information, consult a qualified installer, service

agency or your gas supplier.

Operation of this appliance when not connected

to a properly installed and maintained venting

system can result in carbon monoxide (CO)

poisoning and possible death.

Carbon monoxide poisoning – early signs of

carbon monoxide poisoning resemble the flu

with headaches, dizziness, or nausea. If you

have these signs, get fresh air at once! Have

the heater inspected by a qualified service

technician. Some people are more affected by

carbon monoxide than others. These include

pregnant women, people with heart or lung

disease or anemia, those under the influence

of alcohol and those at high altitudes.

Advertising