Lennox Hearth Winslow (PS40) User Manual

Page 10

Advertising
background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Venting

This stove is approved for venting with Type L and Type PL pellet vent

pipe listed to UL 641 and ULC S609. We recommend the use of venting

products manufactured by Security Chimneys International. Single wall

pipe cannot be used with this pellet stove. The stove’s flue collar is 3” in

diameter. An approved wall thimble or approved ceiling firestop must be

used when the pellet pipe passes through a combustible wall or ceiling.

The stove’s combustion blower pressurizes and pushes flue gases out

the pellet pipe. As a result, all pipe joints should be locked together or

screwed with three screws if the pipe does not have a locking system

and sealed with high temperature silicone. The pipe should be siliconed

and fastened with three screws to the stove’s flue collar.

Where the venting may pass through a wall, or partition of combus-

tible materials, the installation shall conform to CAN/CSA-B365. When

installing the wall thimble and other venting components, follow the

vent manufacturers instructions. Maintain an effective vapor barrier at

the location where the chimney or other component penetrates to the

exterior of the structure.

The longer the run of pipe and the more elbows used, the greater the

resistance to the flow of flue gases. Four inch diameter pellet pipe is

recommended for pipe runs greater than 15 feet or when a number of

elbows are used.

To aid in cleaning, whenever possible, the venting system should include

a tee with clean out attached to the flue collar on the stove.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING

SYSTEM OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A

CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

Horizontal installations that terminate without any vertical sections of

pipe are approved; however, wind may direct flue gases toward the house

causing discoloring problems. For this reason, horizontal and up 5 feet or

horizontal and through the eave installations are recommended.

Wood Stove

Pipe Retrofit

The Winslow PS40

stove stove can be

vented into existing

6” or 8” diameter

wood stove pipe.

45°

90°

Horizontal and UP 5’

Horizontal and Up

Through the Eave

1 foot

minimum

Horizontal

Figure 12

Figure 15

Figure 14

Figure 13

INSTALLATION

Advertising