8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

HEARTH PROTECTION

VENT TERMINATION REQUIREMENTS

The floor protector must be a non-combustible material extending beneath

the stove and to the front and sides as shown below.

Minimum Size Hearth Protection

1. Do not terminate the vent in any enclosed or semi-enclosed areas

such as a carport, garage, attic, crawlspace, narrow walkway, closely

fenced area, under a sundeck or porch, or any location that can build

up a concentration of fumes such as stairwells, covered breezeway,

etc.

2. Vent surfaces can become hot enough to cause burns if touched.

Non-combustible shielding or guards may be required.

3. Termination must exhaust above the inlet elevation. It is recommended

that at least five feet of vertical pipe be installed outside when the

stove is vented directly through a wall. This will create a natural draft

to prevent the possibility of smoke or odor during appliance shut

down or power failure and avoid exposing people or shrubs to high

temperatures.

4. The vent should terminate no less than four feet below, no less than

four feet horizontally from and no less than one foot above doors and

windows, or gravity/ventilation air inlets into the building.

5. The distance between the bottom of termination and grade should be

a minimum of 12” (305 mm). The distance between the bottom of

the termination and a public walkway should be a minimum of seven

feet.

6. Locate the vent termination at least two feet away from combustible

materials such as shrubs, plants, grass, fences, roof overhangs and

adjacent buildings.

Stove Base

Firebox Front Edge

Hearth Protection

Outline of Stove Base

3-7/8”

(98mm)

6”

(15mm)

6”

(15mm)

6”

(15mm)

3-7/8”

(98mm)

9-5/8”

(45mm)

14-1/4”

(36mm)

9-5/8”

(45mm)

10-3/4”

(73mm)

8-7/8”

(5mm)

8-7/8”

(13mm)

7-9/16”

(19mm)

18-3/8”

(467mm)

7-9/16”

(19mm)

33-1/”

(851mm)

8”

(711mm)

Figure 9

Figure 10

Alcove Installations

Minimum alcove height is 41” (1041 mm), minimum width is 42-1/4” (1073

mm) and maximum depth is 48” (1219 mm). Note, it is quite difficult to

load pellets into the hopper when installed in an alcove only 41” (1041

mm) high. For alcove wall clearances see parallel clearances below.

48”

(119mm)

Figure 8

41”

(1041mm)

4-1/4”

(1073mm)