CONDITION

ACTION

Unit Inoperative

A.

No input power. Check main line (user's) switch fuses -- replace if needed.

B. Poor or improper input (terminal board) connections.

C. Defective on/off switch on front panel -- replace.
D. Main transformer overheating. Also check for proper cooling, proper primary hookup,

or shorted turn on secondary.

E. Fan motor not operating -- check motor and leads.
F.

Gound fault indicator "ON". - Check for cause and correct. Turn power switch "OFF"
then "ON" to reset.

G

Loss of primary phase. Check that LED on control PCB is lit. If not, find & replace
defective fuse.

No Output - Fan

A.

Poor or improper electrical input -- check input connections on TB.

Running

B. Poor connections at output terminals/work station -- check, tighten or replace.

C. Main transformer overheating -- thermal switches tripped due to restricted cooling air.

Temperature light on front panel will be lit. Let unit cool down,

D. Solid-state breaker tripped due to current overload.

E. PC board defective or loose PC board connector(s) -- if loose, reinsert; if defective,

replace.

Limited Output or Low

A.

Input voltage jumper links on terminal board improperly set -- check for proper voltage.

Open-Circuit Voltage

Poor output connections. Take apart, clean, and reassemble.

B. Unit may be single phasing -- check incoming power for three phases.

C. Panel-Remote switch in Remote position and remote voltage pot disabled.

Erratic Weld Current

A.

Welding cable size too small -- use correct cables.

B. Loose welding cable connection (will usually get hot) -- tighten all connections.

C. Improper wire feeder setup.
D. Defective SCR in bridge rectifier.

E. PC board defective -- replace.

High Output, No

A.

PC board defective or loose -- reset and/or replace board.

Voltage Control
No 115 Volt ac Output

A.

Circuit breaker tripped. Check 42V CB1 and 115V CB2 -- Reset.

Line Fuse Blows When A.

Shorted SCR in Main Bridge -- replace.

Power Source is First
Turned On