Lenovo THINKCENTRE 8177 User Manual

Page 69

Advertising
background image

Diagnostic

Error

Code

FRU/Action

001-027-XXX

System

Configuration/Setup

error

1.

Run

Setup

2.

Flash

the

system.

See

“Flash

update

procedures”

on

page

214

3.

System

board

001-032-XXX

System

Device

Controller

failure

System

board

001-034-XXX

System

Device

Buffer

Allocation

failure

1.

Reboot

the

system

2.

Flash

the

system.

See

“Flash

update

procedures”

on

page

214

3.

Run

memory

test

4.

System

board

001-035-XXX

System

Device

Reset

condition

detected

System

board

001-036-XXX

System

Register

error

System

board

001-038-XXX

System

Extension

failure

1.

Adapter

card

2.

System

board

001-039-XXX

System

DMI

data

structure

error

1.

Flash

the

system.

See

“Flash

update

procedures”

on

page

214

2.

System

board

001-040-XXX

System

IRQ

failure

1.

Power-off/on

system

and

re-test

2.

System

board

001-041-XXX

System

DMA

failure

1.

Power-off/on

system

and

re-test

2.

System

board

001-195-XXX

System

Test

aborted

by

user

Information

only

Re-start

the

test,

if

necessary

001-196-XXX

System

test

halt,

error

threshold

exceeded

1.

Press

F3

to

review

the

log

file

2.

Re-start

the

test

to

reset

the

log

file

001-197-XXX

System

test

warning

1.

Make

sure

the

component

that

is

called

out

is

connected

and/or

enabled.

See

Chapter

6,

“Using

the

Setup

Utility,”

on

page

55

2.

Re-run

test

3.

Replace

the

component

that

is

called

out

in

warning

statement

4.

Replace

the

component

under

test

001-198-XXX

System

test

aborted

1.

If

a

component

is

called

out,

make

sure

it

is

connected

and/or

enabled.

See

Chapter

6,

“Using

the

Setup

Utility,”

on

page

55

2.

Flash

the

system

and

retest.

See

“Flash

update

procedures”

on

page

214

3.

Go

to

“Undetermined

problems”

on

page

90

Chapter

7.

Symptom-to-FRU

Index

63

Advertising