Trolling Motor Bracket Installation
(single-frequency only)
1. Attach the optional TMB-S bracket to the transducer as shown in the

following figure, using the hardware supplied with the transducer.

(Note: The internal tooth washer is supplied with the TMB-S.)

Attach motor mounting bracket to transducer.

2. Slide the adjustable strap supplied with the TMB-S through the slot

in the transducer bracket and wrap it around the trolling motor. Po-

sition the transducer to aim straight down when the motor is in the

water. Tighten the strap securely.

3. Route the transducer cable alongside the trolling motor shaft. Use

plastic ties (not included) to attach the transducer cable to the troll-

ing motor shaft. Make sure there is enough slack in the cable for the

motor to turn freely. Route the cable to the sonar unit and the trans-

ducer is ready for use.

Transducer mounted on trolling motor, side view.

Transducer Orientation and Fish Arches
If you do not get good fish arches on your display, it could be because

the transducer is not parallel with the ground when the boat is at rest

in the water or at slow trolling speeds.

Bolt

Internal tooth washer

Nut

Flat washer

TMB-S bracket